Using a Punchdown Tool (110) to install a Leviton Gigamax Network Jack

This post outlines how to use a Punchdown Tool (110) to install a Leviton Cat 5e Network Jack and the decommission of the associated box that you could put it in.

Prerequisites: 
- Punchdown Tool (110)
- Leviton Cat5e Gigamax Network Jack
- Cat5e+ Network Cable

 Removing the Jack from the Box:
1. Apply some pressure removing the back piece from the front overlay on the box.


2.  This will reveal the inside of the Box, flip it over so you can get access to the back tab and apply pressure to release the Jack from the box.




Adding/Removing Cable from the Jack:
1. Take off the top cover from the Jack

2. This will reveal the pin-outs, using a 110 Tool you can push your new cable in, or simply remove the old cabling that has been installed.


3. The color coding is marked along the bottom of the Jack depending if you are T568A or T568B. Typically I use T568A being in North America.




Comments

Popular posts from this blog

How to setup a Host-Check for Fortigate SSL VPN

This document outlines how to setup a host-check for a Fortigate SSL VPN (Web only): config vpn ssl web portal edit "portalname" set web-mode enable set host-check custom set host-check-policy "Microsoft-Windows-Firewall" set os-check-enable set ip-pools "PoolName" set split-tunneling disable set page-layout double-column set theme orange config os-check-list "windows-7" set action check-up-to-date set latest-patch-level 1 end  config vpn ssl web host-check-software edit "Microsoft-Windows-Firewall" config check-item-list edit 1 set target "HKLM\\SYSTEM\\CurrentControlSet\\Services\\SharedAccess\\Parameters\\FirewallPolicy\\StandardProfile:EnableFirewall==1" set type registry next edit 2 set target "HKLM\\SYSTEM\\CurrentControlSet\\Services\\SharedAccess\\Parameters\\FirewallPolicy\\PublicProfile:EnableFirewall==1" set type registry next edit 3 set target "HKLM\\SYSTEM\\CurrentControlSet\\S...

Implementing 802.1X - Windows 2012R2 + Cisco 4500 Switches

Implementing 802.1X Using Windows Server 2012R2 & Cisco 4500 Series Switches Overview: This document is to outline how the configuration between Windows Server 2012 R2’s NPS Services and Cisco 4500 Series switches has been implemented. High Level Diagram:   Requirements: Windows Server 2012 R2 with NPS Server installed Windows Server 2012 R2 with CA Services Windows AD Environment Cisco 4500 Series Switches Windows 7-10 Clients to connect NPS Configuration: 1. This assumes the above requirement that the NPS Service has already been installed on Windows Server 2012 R2 2. Disable all existing Policies under Connection Request Policies and Network Policies as you will be making your own, except one that states “Catch All” with the below parameters: 3. You will then need to add in a new Radius Client to have Policies built around. Friendly Name will be used going forward for the Policies for referencing the document. 4. Once completed...

OVA/OVF Templates and Older Versions of VMware ESXI

Recently ran into this issue which I feel is something that I should document, as it provides some additional details onto how to configure or modify an existing .ova or .ovf file which is the standard deployment template for ESXI/VMware. Here was the issue: - ESXI 5.5 - OVA required hardware type 8. Gave an error of  " Unsupported hardware version - vmx-8" when testing. Based on everything I was reading, it isn't supported. So using the ovftool which can be found on VMware's Website ( here ) you can basically extract out the ova/ovf file into a directory, and then use it to modify the VMX file and then put it all back together. Steps: 1. Download the application and install it. 2. Go to the directory where the ovftool is stored via cmd line (Typically C:\Programs Files\Vmware\ect..) 3. Issue the following command: ovftool 4. Then modify the .vmx file so that it contains now the hardware ID of 7 (or whatever you need set for your release). 5. Then issu...